HOMEPRODUCTS FIRE RESISTING CABLES(Fireguard)

 

Fire retardant cable(Fireguard)

Flame Retardant RS485 Databus Cables

 


APPLICATION:

The cables are designed for RS485 data connections where continued functionality is required during a fire situation. This cable combines low capacitance insulation with one of the highest levels of screening to provide high speed, interference free, data transmission where continued functionality is required during a fire situation.

STANDARDS:

Basic design adapted to EIA/TIA 485

Flame Retardant RS485 Databus Cables

FIRE PERFORMANCE:

Flame Retardance (Single Vertical Wire Test) : BS EN 60332-1-2

CABLE CONSTRUCTION:

MULTIPAIR RS 485 OVERALL SCREENED DATABUS CABLE

Conductors: Tinned copper wire, stranded according to IEC 60228 class 2.

Insulation: Foam PE or foam skin PE.

Cabling Elements: Insulated cores are twisted to form pairs with varying lay length to minimize crosstalk. Two pair cable had four cores laid in quad formation.

Cabling: Pairs are cabled together in concentric layers.

Overall Screen: Aluminum/polyester tape with tinned copper drain wire.

Outer Sheath: Thermoplastic PVC compound.

Outer Sheath Option: UV resistance, hydrocarbon resistance, oil resistance, anti-rodent and anti-termite properties can be offered as option. Compliance to fire performance standard (IEC 60332-1, IEC 60332-3, UL 1581, UL 1666 etc) depends on the oxygen index of the PVC compound and the overall cable design. LSPVC can also be provided upon request.

MULTIPAIR RS 485 OVERALL DOUBLE SCREENED DATABUS CABLE

Conductors: Tinned copper wire, stranded according to IEC 60228 class 2.

Insulation: Foam PE or foam skin PE.

Cabling Elements: Insulated cores are twisted to form pairs with varying lay length to minimize crosstalk. Two pair cable had four cores laid in quad formation.

Cabling: Pairs are cabled together in concentric layers.

Overall Screen: Aluminium/polyester tape+copper wire braid.

Outer Sheath: Thermoplastic PVC compound.

Outer Sheath Option: UV resistance, hydrocarbon resistance, oil resistance, anti-rodent and anti-termite properties can be offered as option. Compliance to fire performance standard (IEC 60332-1, IEC 60332-3, UL 1581, UL 1666 etc) depends on the oxygen index of the PVC compound and the overall cable design. LSPVC can also be provided upon request.

MULTIPAIR RS 485 INDIVIDUAL & OVERALL SCREENED DATABUS CABLE

Conductors: Tinned copper wire, stranded according to IEC 60228 class 2.

Insulation: Foam PE or foam skin PE.

Cabling Elements: Insulated cores are twisted to form pairs with varying lay length to minimize crosstalk. Two pair cable had four cores laid in quad formation.

Cabling: Pairs are cabled together in concentric layers.

Individual Screen: Individual aluminium/polyester tape.

Overall Screen: Copper wire braid.

Outer Sheath: Thermoplastic PVC compound.

Outer Sheath Option: UV resistance, hydrocarbon resistance, oil resistance, anti-rodent and anti-termite properties can be offered as option. Compliance to fire performance standard (IEC 60332-1, IEC 60332-3, UL 1581, UL 1666 etc) depends on the oxygen index of the PVC compound and the overall cable design. LSPVC can also be provided upon request.

MULTIPAIR RS 485 OVERALL SCREENED DATABUS CABLE

Conductors: Tinned copper wire, stranded according to IEC 60228 class 2.

Insulation: Foam PE or foam skin PE.

Cabling Elements: Insulated cores are twisted to form pairs with varying lay length to minimize crosstalk. Two pair cable had four cores laid in quad formation.

Cabling: Pairs are cabled together in concentric layers.

Overall Screen: Copper wire braid.

Outer Sheath: Thermoplastic PVC compound.

Outer Sheath Option: UV resistance, hydrocarbon resistance, oil resistance, anti-rodent and anti-termite properties can be offered as option. Compliance to fire performance standard (IEC 60332-1, IEC 60332-3, UL 1581, UL 1666 etc) depends on the oxygen index of the PVC compound and the overall cable design. LSPVC can also be provided upon request.

PHYSICAL AND THERMAL PROPERTIES:

Temperature range during operation (fixed state) : -20°C - +90°C

Temperature range during installation (mobile state) : -5°C - +60°C

Minimum bending radius : 8 x Overall Diameter

ELECTRICAL PROPERTIES:

Dielectric test

1000 V r.m.s. for 5’ (core-core)

1000 V r.m.s. for 5’ (core-screen)

Impedance

120Ω

Capacitance

45 nF/km conductor to conductor

90 nF/km conductor to shield

CONSTRUCTION PARAMETERS:

Multipair RS 485 Overall Screened Databus Cable

RE-02Y(St)Y / RE-02YS(St)Y

No.of Pair Nominal Cross Sectional Area No./Nominal Diameter of Strands Nominal Insulation Thickness Nominal Sheath Thickness Approx. Overall Diameter Approx. Weight
No. mm2 No/mm mm mm mm kg/km

1

0.22

7/0.2

0.7

1.1

5.7

40

2

0.22

7/0.2

0.7

1.1

9.0

72

4

0.22

7/0.2

0.7

1.1

10.3

103

1

0.50

16/0.2

0.7

1.1

6.2

52

2

0.50

16/0.2

0.7

1.1

10.1

95

4

0.50

16/0.2

0.7

1.1

11.7

143

1

0.75

24/0.2

0.7

1.1

6.7

61

2

0.75

24/0.2

0.7

1.1

10.9

114

4

0.75

24/0.2

0.7

1.1

12.7

176

1

1.00

30/0.2

0.7

1.1

6.8

67

2

1.00

30/0.2

0.7

1.1

11.2

122

4

1.00

30/0.2

0.7

1.1

13.0

192

Multipair RS 485 Overall Double Screened Databus Cable
RE-02Y(St)CY / RE-02YS(St)CY


No.of Pair
Nominal Cross Sectional Area No./Nominal Diameter of Strands Nominal Insulation Thickness Nominal Sheath Thickness Approx. Overall Diameter Approx. Weight
No. mm2 No/mm mm mm mm kg/km

1

0.22

7/0.2

0.7

1.1

6.2

55

2

0.22

7/0.2

0.7

1.1

9.4

98

4

0.22

7/0.2

0.7

1.1

10.8

133

1

0.50

16/0.2

0.7

1.1

6.7

68

2

0.50

16/0.2

0.7

1.1

10.6

124

4

0.50

16/0.2

0.7

1.1

12.1

177

1

0.75

24/0.2

0.7

1.1

7.1

79

2

0.75

24/0.2

0.7

1.1

11.4

146

4

0.75

24/0.2

0.7

1.1

13.2

214

1

1.00

30/0.2

0.7

1.1

7.3

85

2

1.00

30/0.2

0.7

1.1

11.7

154

4

1.00

30/0.2

0.7

1.1

13.5

231

Multipair RS 485 Individual & Overall Screened Databus Cable
RE-02Y(St)CY PiMF / RE-02YS(St)CY PiMF


No.of Pair
Nominal Cross Sectional Area No./Nominal Diameter of Strands Nominal Insulation Thickness Nominal Sheath Thickness Approx. Overall Diameter Approx. Weight
No. mm2 No/mm mm mm mm kg/km

1

0.22

7/0.2

0.7

1.1

6.4

56

2

0.22

7/0.2

0.7

1.1

10.2

101

4

0.22

7/0.2

0.7

1.1

11.7

139

1

0.50

16/0.2

0.7

1.1

7.0

69

2

0.50

16/0.2

0.7

1.1

11.4

128

4

0.50

16/0.2

0.7

1.1

13.2

184

1

0.75

24/0.2

0.7

1.1

7.5

80

2

0.75

24/0.2

0.7

1.1

12.3

150

4

0.75

24/0.2

0.7

1.1

14.3

221

1

1.00

30/0.2

0.7

1.1

7.6

86

2

1.00

30/0.2

0.7

1.1

12.6

159

4

1.00

30/0.2

0.7

1.1

14.7

238

Multipair RS 485 Overall Screened Databus Cable
RE-02YCY / RE-02YSCY


No.of Pair
Nominal Cross Sectional Area No./Nominal Diameter of Strands Nominal Insulation Thickness Nominal Sheath Thickness Approx. Overall Diameter Approx. Weight
No. mm2 No/mm mm mm mm kg/km

1

0.22

7/0.2

0.7

1.1

6.0

51

2

0.22

7/0.2

0.7

1.1

9.2

91

4

0.22

7/0.2

0.7

1.1

10.6

126

1

0.50

16/0.2

0.7

1.1

6.5

64

2

0.50

16/0.2

0.7

1.1

10.4

117

4

0.50

16/0.2

0.7

1.1

12.0

169

1

0.75

24/0.2

0.7

1.1

6.9

74

2

0.75

24/0.2

0.7

1.1

11.2

138

4

0.75

24/0.2

0.7

1.1

13.0

205

1

1.00

30/0.2

0.7

1.1

7.1

80

2

1.00

30/0.2

0.7

1.1

11.5

147

4

1.00

30/0.2

0.7

1.1

13.3

222